Safety Interlock Medical Sterilizer Autoclave With Automatic Leak Test
Safety Interlock Medical Sterilizer Autoclave With Automatic Leak Test
Features
- Multiple safe systems to ensure your smooth operation without safety worry.
- Vertical sliding door stable and easy operation
- Integrated automatic PLC control system with one key operation function
- High quality chamber with fine polished of SUS304 or SUS316L for your selecting
- Flexible loading system suitable for various goods requirements
- Customized orders are available
Parameters
- Model: MD-0.24V
- Door type: Vertical sliding single/double door
- Chamber size: 1500(D)*400(W)*400(H) mm, 240 liters
- External dimension: 1850(D)*1250(W)*1800(H)mm
- Max working pressure: 0.23Mpa
- Working vacuum degree: <-0.086Mpa
- Max working temperature: 134℃
- Net weight: 800Kg
- Utilities (supplied by user)
- Electric power: AC380V, 50Hz, 3Ph/N/E, 3KVA, extra 18KVA for built-in steam generator
- Water: 0.15----0.3MPa, Hardness <50ppm, pH Neutral, 70Kg/cycle
- Compressed air: 0.5~0.7Mpa, 10 liters/min
Specification
This Compact Medical Sterilizer Autoclave is Designed and manufactured according to
ISO 9001, ISO 13485 system and latest moist steam sterilizer related standards, whose obvious
advantae is equipped Multiple Safe Systems to ensure your satisfied using smoothly.
It’s suitable for science institute laboratories, hospital CSSD, clinic, operating room to sterilize
experiment tools, medical instruments,sterile clothing, dressings, vessels, apparatuses,
operating tools,culture medium etc..
Safety System
Door safety
- Chamber pressure is over safe pressure (safe pressure settable range is 0---0.03Mpa), door can not be unsealed or open.
- Double door interlocked, one door can be open upon the other one is closed.
- Sterilization cycle can be started upon the door closed and sealed safely.
- Steam is not allowed into the chamber until the door is sealed.
Pressure safety
- Safety valves are equipped both the chamber and jacket for pressure overloading protection;
- High quality pressure sensors and transmitters are sending accurate pressure data to PLC for safety supervised and controlled
Temperature safety
- High quality temperature sensors and transmitters are sending accurate pressure data to PLC for safety supervised and controlled
- While the temperature is over the requested, PLC system automatic control and adjust it at once, then alarming and recording for user’s treating right away.
- Alarm device, combined aural and visual, is equipped for reminding the safety issue occurre and informing the user to treat it in time.
Sterilization Programs
B-D Test
3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min.
Vacuum Leakage Test
Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization
effect.
Instruments/Tools
3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min.
Clothing
3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min.
Liquid
15 min exchange, expose temperature 121℃, expose time 15 min, cooling time 25 min.
User Programmable
All preset parameters can be resettable; total 15 kinds programs can be customized
Main adjustable parameters
Sterilization temperature rage: at 105°C to 134°C
Sterilization time rage: 0---9999 seconds
Vacuum times: 0---9 times
Drying time: 0---9999 seconds
Applications
This vertical sliding door Laboratory autoclave is suitable for science institutes laboratories,
college laboratories, hospital etc to sterilize medical instruments, sterile clothing, dressings,
vessels, apparatuses, operating tools, culture medium and so on.
The single door autoclave is floor standing installation style, whose compact figure saves your
laboratory installation space. The double door one is convenient for isolation between different
clean area is this double door laboratory autoclave’s obvious characteristic.
Leak Test Program
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.