Pass Through Autoclave
Large Capacity Pass Through Sterilizer PLC Control For Mushroom Cultivation
Specification 1. For a correct sterilization the pressure within the chamber must be at 15 psi for a certain period. This means it will be about 121 ℃ within the cooker. No organism will stay alive during such a temperature. The duration of sterilization time depends a lot on the ingredients of the substrate and the volume of it. The specific sterilization time of specific substrates are mentioned in
Super Heated Hot Water Spray Pass Through Autoclave For IV Solutions
Application This Series sterilizers are mainly used in sterilizing for plastic bottle packing infusion solutions. Using superheated pure water as the sterilization agent, the plastic bottle solutions will be heated quickly, and the temperature in the chamber is uniformly distributed during the cycle because of the water showering continuously. Quality system * cGMP Standard * ISO 9001 quality system * GB-150
Big Touch Screen Interface Pass Through Autoclave 600 Liter For Pharmaceutical Industry
Quality Standards cGMP ISO 9001:2008 - Quality Management Systems ISO 13485:2012 Quality Management System – Medical Devices Applications This series steam autoclaves are designed and manufactured specially for sterilizing medical instruments, sterile clothing, dressings, vessels, apparatuses, operating tools, culture medium etc. Specifications Model MDC-0.6 Door type Motorized Hinge Door
User Friendly HMI Pass Through Autoclave With Pre Vacuum And Post Vacuum Function
Description The MD series pass through autoclave is a fully automatic steam sterilizer. It has pre-set programs for the most common sterilization processes for general purpose hospital use. The program cycles employ mechanical air removal with a series of vacuum/pressure pulses to effectively remove air for assured sterilization. The chamber dimensions are adapted to sterilization. Key Features
SS316L Chamber Steam Pass Through Autoclave With PT-100 Temperature Sensor
Key Features 1. Hinged door with automatic locking 2. Temperature range: 105°C - 134°C 3. Lower operating cost 4. Delicate Heating With Steam 5. Water Ring Vacuum Pump 6. 0.22 Micron Air Filter 7. Sterilization agent: Saturated steam 8. Chamber : SS 316L Quality and Heating Jacket : SS 304 9. Micro-printer recorder 10. With stainless steel trays 11. Special design for BSL3 and BSL4 laboratories
Horizontal Sliding Door 1500 Liters Stainless Steel Pass Through Sterilization Cycle Autoclave
Application Pass through steam sterilization offers a wide range of application and is mainly used in the harmaceutical and biotechnology industries. Main application can be sterilization of - Porous load, stainless steel instruments, empty bottles, vials and plastic containers, filters and stoppers. - Solution in Glass container like ampoules, vials and bottles - Terminal
Colored Touch Screen Pass Through Lab Autoclaves With Low Power Consumption
Why Our Pass Through Autoclave? Low maintenance cost Reliable performance of the sterilization operation Easy to operate Low power consumption Operating Parameters Sterilization temperature rage: 105 --- 134°C Sterilization time rage: 0---99 minutes Vacuum times: 0---9 times Drying time: 0---99 minutes Key Features Inter connecting 304 stainless steel steam piping Pneumatically actuated Valve Spring
PLC Control Sterilizer Autoclave With Pass Through Motorized Hinge Door
Specification High quality chamber with fine polished of SS304 or SS316L Flexible loading system suitable for various goods requirements High effective liquid-ring vacuum pump for saving energy Excellent ergonomics together with well-adapted accessories Touch screen technology for high user interaction Possibility to have the technical area for easy maintain on both sides Integrated automatic PLC control
High Pressure High Temperature Pass Through Sliding Door Pharmaceutical Sterilizer With 6 Cycles
Specifications Model Chamber Size Overall Size Net Weight Steam Water Power W*H*D mm W*H*D mm Kg Kg/cycle Kg/cycle KVA MD-1.0Y 680*1180*1250 2200*2000*1660 1630 40 100 4 Program Parameter Cycle name Further details Application Instruments/Tools 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. Solid materials to be sterilized: ●Packaged instruments
Stainless Steel 304 Pass Through Autoclave With HMI Control System
Key Features Double Door Pass-Through Autoclave Safe, Reliable And EconomicalChamber Volume 240 LitersMicroprocessor Control, Simple And Clear OperationWide Offer Of Sterilization ProgramsWorking Temperature: 105 °c To 134 °cIndividual Job-Order ManufactureHeat Resistant Silicon Rubber Gasket In Accord With cFDA Regulations.SIP And Integrity Testing Port.Interlocks Protect Against Passage Of Contaminated
Multiple Sterilization Cycles Compact Pass Through Autoclave With HMI Screen
Key Features cGMP Pharmaceutical autoclave 360 Liter chamber volume Steam sterilizing agent Built to conform to end-user-requirements (URS) AISI 304 stainless steel chamber and jacket Motorized hinge door stable and easy operation Touch screen technology for high user interaction High effective liquid-ring vacuum pump for saving energy Integrated automatic PLC control system Micro-printer recorder
High Temperature Hot Air Pass Through Autoclave With Hot Air Circulation
Description Positive Pressure throughout the cycle for 100% Sterile integrity of the load. Automatic PLC controlled cycle with user-friendly operator interface for visual monitor and control over the entire cycle. Temperature Controller for overshoots temperature condition. From the point of view of chamber safety, the heater bank and fan motor are electrically interlocked. Sterile door lock to prevent