CSSD Sterilizer
Single Door 316L Chamber CSSD Sterilizer With Steam Generator Touch Screen
Description This series steam autoclaves are designed and manufactured specially for hospital CSSD, operating room to sterilizing medical instruments, sterile clothing, dressings, vessels, apparatuses, operating tools, culture medium etc. Key features - Improve productivity and maximize reliability and uptime - User-friendly - Safe and ergonomic - Different configurations to fit the volume and workflow
Horizontal Loading Compact Steam CSSD Sterilizer with PLC Controlled
Sterilization Cycles Cycle name Further details Application Instruments/Tools 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. Solid materials to be sterilized: ●Packaged instruments ●Empty glass containers ●Empty metal containers Porous materials to be sterilized: ●Rubber articles Clothing 3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min.
Vertical Sliding Door 100Liters Capacity Hospital CSSD Sterilizer With Micro Printer
Main Parameters Model Chamber Size Overall Size Net Weight Steam Water Power W*H*D mm W*H*D mm Kg Kg/cycle Kg/cycle KVA MD-0.10V 400*400*700 1000*1800*1040 650 14 15 2 MD-0.16V 400*400*1000 1000*1800*1340 700 16 20 2 MD-0.20V 400*400*1300 1000*1800*1640 750 18 25 2 MD-0.24V 600*600*670 1200*2000*1010 800 20 30 2 MD-0.30V 600*600*840 1200*2000*1180 850 22 35 2 MD-0.36V 600*600*1000 1200*2000
Horizontal Hinge Door CSSD Sterilizer 600 Liter With Built-in Steam Generator
Brief The new, recently designed sterilizer was created through careful selection of materials, components and technical solutions that ensure durability, productivity and functional safety at every moment. All of our machines are constructed according to a high standard of reliability and hygiene. Principle features • Sterilization chamber made of AISI 316L stainless steel, jacket and door built in
Saturated Steam CSSD Sterilizer With Water Ring Vacuum Pump and Pneumatic Valve
Specification Model Chamber Size Overall Size Net Weight Steam Water Power W*H*D mm W*H*D mm Kg Kg/cycle Kg/cycle KVA MD-1.0Y 680*1180*1250 2200*2000*1660 1630 40 100 4 Program Parameter Cycle name Further details Application Instruments/Tools 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. Solid materials to be sterilized: ●Packaged instruments ●Empty glass
High Pressure Muti Cycle Selection CSSD Sterilizer For Hospital B-D Test
Sterilization Cycles Cycle No. Cycle Name Further Details 1 Instruments/Tools 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. 2 Clothing 3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. 3 Liquid 15 min exchange, expose temperature 121℃, expose time 15 min, cooling time 25 min. 4 B-D Test 3 times Vacuum, expose temperature 134℃, expose time 4
Automatic Hinge Door CSSD Sterilizer 1000 Liter With Safety Working System
Features · The inner chamber is fabricated from S.S. 316 or S.S. 316L and is fully welded to ensure a crevice free and easy to clean environment. · Temperature Uniformity +/- 1 degree Celsius guaranteed within the chamber for the entire cycle. · Air filter of 99.97% performance for clean air. · Positive Pressure throughout the cycle for 100% Sterile integrity of the load. · Automatic PLC controlled
Bio-contaminated CSSD Sterilizer With Several Steam And Vacuum Pulses
Bio-contaminated CSSD Sterilizer With Several Steam And Vacuum Pulses Specifications MD-0.8Y CSSD sterilizer outside size (W*H*D): 220*200*141cm Inside chamber size (W*H*D):68*118*100cm Net weight: 1480kg Power: 3KVA, AC380v,50Hz, three phases Water: 80kg/cycle, softened water, hardness