Laboratory Veterinary Medical Devices With Independent Recording For Animal Research Center
Features
-
Automatic sliding doors with safety edge and auto-reverse system.
-
Pre/post vacuum system Air detector.
-
Steam jacket for optimum drying performance
-
8-program user-friendly touch screen control system.
-
Thermal data printer
-
E-Stop
-
Clean steam option
A part of size for selection
|
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
|
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
|
MD-0.11V |
400*400*700 |
1000*1800*1040 |
650 |
14 |
15 |
2 |
|
MD-0.16V |
400*400*1000 |
1000*1800*1340 |
700 |
16 |
20 |
2 |
|
MD-0.20V |
400*400*1300 |
1000*1800*1640 |
750 |
18 |
25 |
2 |
|
MD-0.24V |
600*600*670 |
1200*2000*1010 |
800 |
20 |
30 |
2 |
|
MD-0.30V |
600*600*840 |
1200*2000*1180 |
850 |
22 |
35 |
2 |
|
MD-0.36V |
600*600*1000 |
1200*2000*1340 |
900 |
25 |
40 |
2 |
|
MD-0.45V |
600*600*1250 |
1200*2000*1590 |
980 |
27 |
50 |
2 |
|
MD-0.60V |
600*600*1670 |
1200*2000*2010 |
1100 |
30 |
60 |
3 |
Description
• Our range of porous load rectangular chambered sterilizers are available in six standard sizes
and 110 to 600 liters.
• All models can be configured for either single entry or pass-through. All models are fitted with a
wide selection of features as standard, all designed to ensure optimum performance and the
fastest possible cycle times.
• In addition to traditional loading trolley systems, Medpharm is also able to provide assisted and
automated loading solutions.
• Pass-Through: Available throughout range
• Section: Square or Rectangular
• Loading: Front
• Heating Source: Integral/stand-alone steam generator or direct steam supply
Cycles
|
Cycle name |
Further details |
Application |
|
Instruments/Tools |
3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. |
Solid materials to be sterilized: ●Packaged instruments ●Empty glass containers ●Empty metal containers Porous materials to be sterilized: ●Rubber articles |
|
Clothing |
3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. |
Materials to be sterilized from which air can’t be easily displaced ●Textile |
|
User Programmable |
All preset parameters can be reset; Multiple customized programs can be set and stored by user. |
Customized |
|
Test cycles |
||
|
B-D Test |
3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. |
Test program |
|
Vacuum Leak Test |
Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. |
Test program |
Popular Options
1. Loading/Carriage Trolleys
2. Stainless steel pipe work Independent monitoring
3. Air Compressor
4. RO water system
5. Remote data archiving
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.