Large Capacity Pass Through Sterilizer PLC Control For Mushroom Cultivation

Price Negotiable
Price: Negotiation
MOQ: 1 pc
Delivery Time: 30 working days after received your payment
Brand: Medpharm
Product Description

 

Large Capacity  Pass Through Sterilizer PLC Control For Mushroom Cultivation

 

 

Specification

 

1. For a correct sterilization the pressure within the chamber must be at 15 psi for a certain period.

This means it will be about 121 ℃ within the cooker. No organism will stay alive during such a temperature. The duration of sterilization time depends a lot on the ingredients of the substrate and the volume of it. The specific sterilization time of specific substrates are mentioned in the techniques section.

 

2. PLC fully automatic control system: automatic temperature control, automatic pressure control,

automatic sterilizer time control

 

3. Safe operation: electric and mechanical double safety interlock protection system for safe operation

 

4. Overpressure protection: electric and mechanical double overpressure protection system

for safe operation

 

5. Over temperature protection: electric over temperature protection system

 

6. Equalized heat distribution: the temperature inside the reactor is equalized distribution, which

means the temperature difference is less than 1.0℃

 

7. Electrical heating system: the electrical heating tube with the material of stainless steel, one

set reactor with several units of heating tubes to heat the water uniformly and quickly.

 

8. Humanization design and long life span material: stainless steel material, carbon steel, with

high intelligent automatic control system

 

Description

 

1. Mushroom autoclave machine was used the water ring vacuum pumps, vacuum degree

reached less than -0.08 Mpa, at the same time in the process of sterilization, control system,

according to the temperature of the inner chamber of the steam exhaust steam automatic

adjustment.

 

2. Mushroom autoclave machine was design by rectangular structure, this kind of autoclave

has particular pipeline design and advance control system.

 

Applications

 

Widely used in food industry, mushroom sterilization, and other food sterilization field.

 

Competitive Advantage

 

This is a stable technique, which has provided good results over the past twenty years. If any

diseases are discovered, the infected bag of mushroom can be simply removed without the

risk of contaminating the rest of the substrate.

 

Program Parameter

 

Cycle name

Further details

Application

Instruments/Tools

3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min.

Solid materials to be sterilized:

●Packaged instruments

●Empty glass containers

●Empty metal containers

Porous materials to be sterilized:

●Rubber articles

Clothing

3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min.

Materials to be sterilized from which air can’t be easily displaced

●Textile

User Programmable

All preset parameters can be reset; Multiple customized programs can be set and stored by user.

Customized

Test programs

B-D Test

3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min.

Test program

Vacuum LeakTest

Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect.

Test program

 

 

Brochure load down from here

Medpharm medical large steam autoclave brochure.pdf

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ZHANGJIAGANG MEDPHARM MACHINERY LTD.
Location B631, HUAFANG INTERNATIONAL MANSION, No.178 CHENGBEI STR., ZHANGJIAGANG, JIANGSU, PRC, 215600
Contact Person Juliet

Request A Quote

Please check your email address.
Your message must be at least 20 characters.