High Pressure Muti Cycle Selection CSSD Sterilizer For Hospital B-D Test
High Pressure Muti Cycle Selection CSSD Sterilizer For Hospital B-D Test
Sterilization Cycles
|
Cycle No. |
Cycle Name |
Further Details |
|
1 |
Instruments/Tools |
3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. |
|
2 |
Clothing |
3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. |
|
3 |
Liquid |
15 min exchange, expose temperature 121℃, expose time 15 min, cooling time 25 min. |
|
4 |
B-D Test |
3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. |
|
5 |
Vacuum Leak Test |
Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. |
|
6 |
User Programmable |
All preset parameters can be resettable; Multiple customized programs can be set and stored by user. |
Description
Door Safety
- The autoclave doors are designed with a number of independent mechanical and digital safety features.
- A safety device prevents the operator from opening the door when chamber is pressurized
- Steam will not enter the chamber when the door is open.
- A cycle cannot start if the door is open or not properly locked.
- The door cannot unlock until chamber pressure reaches room pressure.
- Sliding Door Safety - sliding door progress will automatically stop if an obstruction is detected.
- Double Door Safety – interlocks prevent both doors from being opened simultaneously.
General Safety Features
- Double Independent Monitoring: The combined electronic and mechanical monitoring ensures that the operator has two independent means to monitor pressure.
- Safety Valves: If the pressure exceeds the allowed limit the safety valves will discharge.
- Built-in Steam Generator Safety: A water level monitoring system maintains a constant water level and ensures safe operation of the heaters.
- Emergency shut-off: Easily accessible emergency switches for immediate cycle shut-off.
Competitive Advantage
- During Sterilization a Microprocessor / PLC controls temperature, Pressure, Steam Injection,
- Sterilization time, Drying and all other critical time based parameters.
- Important sterilization parameters like Phase Status, Current Values & set values, continuously displayed at all times on Controller Screen.
- Continuous display of Temperature and Pressure On-line allows user to be aware of Cycle status at all times.
- Error Code and alarm is generated and cycle stops automatically in case any error occurs.
- Computer Screen displays Error, possible cause and remedy.
- The advanced SCADA software provided stores detailed records of Process- Data for every cycle.
- Reports are available in Data, Summary and Graph formats for every batch of goods sterilized.