21 CFR Part 11 Complied Autoclave Sterilizer Machine with Sterilization Control Selectable On Time Basis
21 CFR Part 11 Complied Autoclave Sterilizer Machine with Sterilization Control Selectable On Time Basis
Features
- Chamber and jacket in stainless steel 316L
- For hospital CSSD, Operating room applications
- Full jacket and chamber surface heating
- Process pipework in stainless steel
- Control panel can be mounted either left or right hand side of machine
- Efficient heat exchanger and quiet vacuum pump
- Automatic powered vertical sliding door
- Pressurised door sealing system
- Microprocessor control
- Multi-level user control
- Chamber fixing positions for carriages or shelves
- ISO 13485 and ISO 9001 compliant
Main Adjustable Parameters
Sterilization temperature rage: at 105°C to 134°C
Sterilization time rage: 0---99 minutes
Vacuum times: 0---9 times
Drying time: 0---99 minutes
Multiple adjustable parameters to ensure user’s customized programs are available, accurate and perfect sterilization effect.
Model Chart
|
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
|
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
|
MD-0.11V |
400*400*700 |
1000*1800*1040 |
650 |
14 |
15 |
2 |
|
MD-0.16V |
400*400*1000 |
1000*1800*1340 |
700 |
16 |
20 |
2 |
|
MD-0.20V |
400*400*1300 |
1000*1800*1640 |
750 |
18 |
25 |
2 |
|
MD-0.24V |
600*600*670 |
1200*2000*1010 |
800 |
20 |
30 |
2 |
|
MD-0.30V |
600*600*840 |
1200*2000*1180 |
850 |
22 |
35 |
2 |
|
MD-0.36V |
600*600*1000 |
1200*2000*1340 |
900 |
25 |
40 |
2 |
|
MD-0.45V |
600*600*1250 |
1200*2000*1590 |
980 |
27 |
50 |
2 |
|
MD-0.60V |
600*600*1670 |
1200*2000*2010 |
1100 |
30 |
60 |
3 |
Offer Of Clients Services
In addition to the device supplies, we offer other range of services related to the development of central and operating room sterilizations
- Counselling and project drawing including the logistics and capacity calculation;
- Turnkey device deliveries including the individual information systems;
- The ability of the sterilization processes to be validated and recorded is one of the conditions for their quality assurance. For these pruposes, the users of STERIVAP steam sterilizers are also offered a new service - Validation
- The technical measurement are performed by own accredited testing laboratory.
Optional Equipment – Multiple Accessories
Extensive accessories program is available for the sterilizers –more than 50 other optional
specific accessories.
The system of manual loading of materials or system of transport and charging carriages is adjusted to the sterilizers size, optional container system and sterilization baskets.
The sectional principle enables building of the device in stainless steel partition walls.
The mirrored version of the device allows uniting two service areas into one.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.

