BSL3 Double Door Laboratory Autoclaves With Effluent Decontamination System
Double Door Laboratory BSL3 Autoclaves With Effluent Decontamination System
Features
- Special design for BSL3 laboratories
- Extreme process reliability
- User-friendly HMI
- Parameters could be easy adjusted for perfect compliance with various customer requirement
- Efficient drying based on a high performance vacuum system
- Minimal media consumption
- Strictly isolated technologies adopted to ensure safety
- No recontamination for environment and human being
BSL3 Special
Consolidated BSL-3 Series Sterilizers are designed to sterilize at temperatures between
220°F and 275°F (104°C and 135°C) through the use of steam.
The BSL-3 Series meet the tough requirement of biocontainment facilities and are typically
installed in Biosafety Level 3 rated laboratories located within any life science, biotechnology,
or animal research (vivarium) facility.
Main Parameters
|
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
|
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
|
MD-0.11V |
400*400*700 |
1000*1800*1040 |
650 |
14 |
15 |
2 |
|
MD-0.16V |
400*400*1000 |
1000*1800*1340 |
700 |
16 |
20 |
2 |
|
MD-0.20V |
400*400*1300 |
1000*1800*1640 |
750 |
18 |
25 |
2 |
|
MD-0.24V |
600*600*670 |
1200*2000*1010 |
800 |
20 |
30 |
2 |
|
MD-0.30V |
600*600*840 |
1200*2000*1180 |
850 |
22 |
35 |
2 |
|
MD-0.36V |
600*600*1000 |
1200*2000*1340 |
900 |
25 |
40 |
2 |
|
MD-0.45V |
600*600*1250 |
1200*2000*1590 |
980 |
27 |
50 |
2 |
|
MD-0.60V |
600*600*1670 |
1200*2000*2010 |
1100 |
30 |
60 |
3 |
Pass-through Door Interlock System
- For pass-thru models only.
- Prevents opening of the sterilizer door on the non-contained side until completion of a
- sterilization cycle.
- Also prevents both doors from being opened simultaneously.
- This system is programmed to accommodate the desired direction of product flow.
Effluent Decontamination System
- Consolidated Sterilizer Systems was one of the first companies to investigate and discover the potential hazards of contaminated sterilizer effluent.
- For labs working with BSL3 micro organisms all waste and effluent must be rendered sterile.
- Sterilization of bacteria and pathogens is accomplished through the use of an FDA approved, ultra high-efficiency filter.
Innovative Automatic Safety Door Lock
- Easy and safe. When the autoclave lid is closed, the lid is automatically locked by a circumferential ring system.
- A special lip seal made of heat resistant silicone provides eliable sealing. As steam pressure builds within the sterilizer, the seal becomes tighter.
- The lid also opens easily –either at the push of a button or automatically at the end of a sterilization cycle.