Stainless Steel 316L Tri Clamp Sample Valves Sanitary Aseptic

Price Negotiable
Price: Negotiable
MOQ: Sample quantity acceptable
Delivery Time: 1-2 weeks
Brand: WLM
Product Description

 

Sanitary Hygienic Aseptic Sampling / Sample Valve

 

Applications:

The sanitary hygienic aseptic sampling valve is also known as aseptic sample valve. They are designed for both fluid sample extraction and valve chamber sterilization before and after sampling. The entire medium sampling process is carried out under aseptic conditions.

 

Sanitary hygienic aseptic sampling / sample valves are typically installed in pipelines or on storage tanks in food, dairy, beverage, beer, wine, pharmaceutical, chemical and biotechnology industrial applications.

 

Configuration:

 

Working Principle:

The aseptic sampling / sample valve is designed for sterilization before and after sampling.

Sterilization process before sampling

1. The steam or sterilization medium is fed into one of sampling port to sterilize valve chamber

2. Another port discharges the sterilization medium

Sampling process

1. Rotate the handle or lift the joystick to open the sample valve

2. The central shaft opens

3. Sampling

4. Close the valve

Sterilization process after sampling

1. Inlet clean water to clean the valve chamber

2. Inject sterilization medium for sterilization

P.S.: The outlet side can be equipped with a pressure regulating valve

 

Technical Specification:

Trademark WLM
Driven Mode Manual or Pneumatic
Size 1/4”, 3/8”, 1/2”, 3/4”, 1”
Valve Opening Pressure Max. 6 bar
Valve Closing Pressure Max. 12 bar (sealing head); Max. 15 bar); Max. 15 bar (stainless steel valve body)
Working Temperature -20 ~ +120℃(EPDM seal) / 130℃(PTFE seal)
Sterilization Temperature 150℃(Max. 20 minutes), dry steam
Surface Finishing Inside surface R<0.8μm; outside surface R<1.6μm

 

 

Precautions of Aseptic Sampling / Sample Valve:

  • When executing CIP for the pipe, the aseptic sampling valve opens automatically, in order to avoid the forming of sanitary dead leg between sealing part and the pipe wall. When the water flushes in the pipe, the valve also opens automatically for a second sterilization.
  • The aseptic sampling vale needs management and maintenance. The frequent open and close of the valve can accelerate the aging of sealing part, which is easy to cause pollution to the medium. So inspections and maintenance should be often carried out to the sealing part of the sampling valve.
  • For steam disinfection, the steam must be dry. The condensate water will damage the diaphragm, so the diaphragm should be changed after every 100 times of sampling and sterilization, or according to working conditions and experience.
  •  

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Linch Machinery Co. Ltd.
Location 9-1216, No. 299, Fangcheng Avenue, Xinwu District, Wuxi, China
Contact Person Sarah Ding

Request A Quote

Please check your email address.
Your message must be at least 20 characters.