GE Voluson E10 Medical Diagnostic Ultrasound Repair
GE Voluson E10 System Reports Error Failure phenomenon The scan area image of GE VOLUSON E10 color ultrasound system is whitish, and restarting is invalid. Failure analysis and Troubleshooting Voluson E10 image problems are common front-end board problems. Diagnose according to the image conditions, replace the RFM board, and troubleshoot after reinstalling the system. Tips: Poor contact between the various components of the ultrasound equipment is a common cause of failure
Repair CX50 Ultrasonic Mainboard 453561368033/453561622163
Repair CX50 Ultrasonic Mainboard (P/N:453561368033/453561622163) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 453561368033/453561622163 4. Compatiable with CX50 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related to that we can offer: Brand Compatible system Description Envisor control panel 453561184013 Envisor TR board M2540
KTI301148 Ultrasound Machine Repair E6 Voluson E8 RST Board
Repair GE Voluson E6/Voluson E8 RST board (P/N: KTI301148) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: KTI301148 4. Compatible with GE VolusonE6/Voluson E8 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq
EP539100BB Aloka Alpha 7 Ultrasound Machine Repair
EP539100BB Ultrasonic Repairing System , Medical Aloka Alpha 7 Repair Repair Aloka RX Assy for Alpha 7 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: EP539100BB//EP539500DG/EP539501DG/EP539100/EP5391/EP5395/EP539500/EP539501/EP5395/539100 4. Compatible with Aloka Alpha 7 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to Aloka that we can offer: Brand System Description
EP537000AB Ultrasound Machine Repair Aloka Alpha 6 Alpha 7 CPU Board
Repair Aloka Alpha 6/Alpha 7 CPU Board (EP537000AB) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: EP537000AB 4. Compatible with Aloka Alpha 6/ Alpha 7 Knowledge point The sleek ProSound Alpha 7 brings ergonomics, portability and premium performance to a new level. The most compact system in its class, the ProSound Alpha 7 inherits its high performance and digital front-end technologies from Hitachi Aloka’s flagship Alpha 10. What’s more, this environmentally
Ywm2056*A Toshiba Ultrasound Machine Repair Aplio 500 RX Board
Ywm2056*A Toshiba Aplio 500 RX Board Ultrasound Machine Repair/Medical Instrument Toshiba Aplio 500 RX Board (ywm2056*a) 1. Model: ywm2056*a 2. Condition: Original, in good working condition 3. With 60 days warranty 4. Compatible with Aplio 500 Outright/exchange/repair is available for ultrasound parts/Assy. Other ultrasound parts that we can offer: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 APS Power Supply 5140505
ALOKA Alpha 5 Ultrasound Machine Repair Color Doppler
ALOKA Alpha 5 color doppler ultrasound fault repair case ALOKA alpha 5 is equipped with advanced front-end technology, original data processing platform,high-capacity digital beam generator (12bit digital beam generator) and other technologies to ensure the high-quality image of all organs in the body.And as well as the varties probes in ALOKA, ALOKA alpha 5 can meet the needs of linical diagnosis and scientific research,At present, ALOKA alpha 5 is used in many hospitals in
PM30-38691 Ultrasound Machine Repair Toshiba Aplio 300 400 500 TX Board
Repair Toshiba Aplio 300/400/500 TX Board PM30-38691/Diagnosis Equipment Repair Toshiba Aplio 300/400/500 TX Board PM30-38691 1. Model: PM30-38691/38691 2. Repair time: 2-4 days 3. With 60 days warranty 4. Compatible with Aplio 300/400/500 Other ultrasound parts that we can offer: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 APS Power Supply 5140505/5166108/5329667 GE Logiq P5 CPU mainboard 5168431 GE Logiq P5 SYSCONPM
SSA 580A Toshiba System Repair , clinic RX board maintenance
Toshiba SSA-580A Maintenance Fault phenomenon The machine starts normally, but there is no echo when it enters the ultrasonic working interface. Fault analysis Ultrasound image echo-free is a typical fault that all major brands of ultrasound machines will encounter. Usually, the reason for the failure is that the front-end plate of the power supply of the machine has no high-voltage output or is responsible for the processing function of ultrasound imaging. It is preliminary
GE Voluson E8 Ultrasound Diagnostic Equipment Repair
GE Voluson E8 System Reports Error Fault phenomenon The GE VOLUSON E8 color ultrasound system has a blue screen and reports that the system file is missing. It is resolved after reinstalling the system, but this failure recurs after a week. Failure analysis and Troubleshooting According to the description, reinstalling the system has solved the fault, indicating that the computer system software crashed, but the same fault occurred a week after it returned to normal. It is
Ultrasound Repair Service Toshiba Xario 200 TX Board PM30-32732-1
Repair Toshiba Xario 200 TX Board (P/N: PM30-32732-1) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: PM30-32732-1 4. Compatible with Toshiba Xario 200 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related to Toshiba that we can offer: Brand System Description Toshiba Famio 5 (SSA-510A) TFT board BSM31-5629 Toshiba Famio 8 SSA-530A PCB board I/O TSB1-20-20226 Toshiba Famio 8 SSA
Fix CX50 Control Board 453561685791/Ultrasound Engineer Technician
Fix CX50 Control Board(P/N: 453561685791) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 453561685791 4. Compatiable with CX50 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related to that we can offer: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX M2540
Ultrasonic Repair Service HD7/Envisor T/R Board 453561448371
Repair HD7/Envisor T/R board 453561448371 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 453561448371 4. Compatiable with HD7/Envisor Other ultrasound parts related to that we can offer: Brand System Description iU22/iE33 Front End Controller 453561278261/453561278266/453561464291/453561153751 iU22/iE33 excelsior motherboard 453561419431/453561382231/453561419431 iU22/iE33 Unified Motherboard 453561254492 453561360251 iE33 G Cart Channel Board 453561303332 iE33
Medical Ultrasound Machine Repair Aloka Alpha 7 TX Board PN: EP548300BB ultrasound parts
Medical Ultrasound Machine Repair Aloka Alpha 7 TX Board PN: EP548300BB ultrasound parts 1 .Model: EP548300BB 2. Repair time: 2-4 days 3. We provide 60 days warranty after repaired Other ultrasound parts related to Aloka that we can offer: Brand System Description Aloka SSD-1000 CPU EP448902BB Aloka SSD-1000 CPU EP453000 Aloka SSD-1000 power board EU-6025B Aloka SSD-1000 TI board EP401500EH Aloka SSD-1000 EP400600CH Aloka SSD-1000 EP3996 EP3997 Aloka SSD-1000 EP395601DF Aloka
Biosound Mylab 40 Measurement Ultrasound Machine Repair Replace Mainboard
Biosound Mylab 40 Measurement Cannot Be Used Ultrasound Machine Repair Replace Mainboard 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Measurement Cannot Be Used Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can offer: Brand System Description Biosound Mylab 20 plus/30/40 CPU mainboard 9501361000 Biosound MyLab 25 power board 9501083010 4271440192 Biosound MyLab
GE BEP Power Ultrasound Machine Repair For Logiq E9 5393800-3 5166790-2
Repair GE BEP power for Logiq E9 (P/N:5393800-3,5166790-2) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 5393800-3/ 5166790-2 4. Compatible with GE Logiq E9 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq
EP558800 Ultrasound Machine Repair Hitachi Aloka F75 CPU Cell Board
Repair Hitachi Aloka F75 CPU Cell Board (P/N:EP558800) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: EP558800/EP5588/558800 4. Compatible with Hitachi Aloka F75 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to Aloka that we can offer: Brand System Description Aloka SSD-1000 CPU EP448902BB Aloka SSD-1000 CPU EP453000 Aloka SSD-1000 power board EU-6025B Aloka SSD-1000 TI
Toshiba Aplio 300 Ultrasound Machine Repair Numeric Keypad Not Working Occasional Control Panel Failure
Toshiba Aplio 300 Ultrasound Repair Numeric Keypad Not Working And Occasional Control Panel Failure 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Numeric Keypad Not Working And Occasional Control Panel Failure Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related to Toshiba that we can offer: Brand Compatible System Description Toshiba Famio 5 (SSA-510A) TFT board BSM31-5629
RSX Ultrasound Machine Repair For GE Voluson E6 E8 E10
Repair GE Voluson E6/E8/E10 RSX (P/N: KTZ303054 /KTI303054) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: KTZ303054/KTI303054 4. Compatible with GE Voluson E6/E8/E10 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE
EPIQ 7 Ultrasound Machine Repair
EPIQ 7 system reports error "511" Failure phenomenon The EPIQ 7 Ultrasound was suddenly powered off during use, and then suddenly powered off after it was powered on. After encountering two sudden power failures, it turned on again. An abnormal startup failure occurred. The display stayed on the "" interface for a long time, and finally entered the boot interface. Error "511" is reported, and the device cannot be used normally. Failure analysi